- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chart Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Power Supply
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
PULSAR GREYLINE DFM 6.1 Ultrasonic Doppler Flow Meter
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The Greyline Instruments DFM 6.1 Doppler Flow Meter is a simple, non-contact meter designed for applications that would defeat regular contacting flow meters. Because the sensor is mounted on the outside of the pipe, it is unaffected by abrasives or harsh chemicals making it ideal for wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. There is no obstruction to flow and no pressure drop. The DFM 6.1 is recommended for full pipes and any fluid that contains solids or bubbles.
The DFM 6.1 clamp-on sensor is mounted on the outside of any pipe 1/2in / 12.7mm diameter or larger. To measure velocity an acoustic signal is reflected back to the sensor from moving particles or gas bubbles suspended in the fluid. Flow is calculated based on configured pipe ID.
Features:
Flow rate: ±0.1 to 40 ft/sec (±0.03 to 12.2 m/sec)
Pipe size: 1/2 to 180in (12.7mm to 4.5m)
Accuracy ±2%:
Requires solids or bubbles of at least 100 microns
75ppm concentration
±0.1%, Linearity ±0.5% of full scale repeatability
Large, backlit LCD display
16-Digit totalizer
Reverse flow measurement
Isolated 4-20mA (1000 ohm load max)
2 programmable control relays
26 Million Point Data Logger
What's In The Box:
(1) Power supply
(1) Transducer mounting hardware
(1) Transducer cable
(1) Installation and operation manual