- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Power Supply
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
PULSAR GREYLINE DLT 2.0 Differential Level Transmitter
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The Greyline Instruments DLT 2.0 differential level transmitter uses two non-contacting ultrasonic sensors to provide differential level and control as well as open channel flow monitoring. This versatility reduces costs and simplifies instrumentation and makes the DLT 2.0 a great solution for barscreen level control at wastewater treatment plants, pump stations and combined sewer systems.
The DLT 2.0 can measure both differential level plus flow through a flume. It includes two non-contacting ultrasonic sensors to measure level. With sensors positioned above a channel, up and downstream from the barscreen, the DLT 2.0 can display and transmit differential level. The downstream sensor can also be installed above a flume or weir to measure and totalize open channel flow.
The DLT 2.0 is easy to set up and operate. Simply use the built-in 5-button keypad/menu system to input the calibration parameters. Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow) and differential level. Built-in relays can be calibrated for level control, differential level control or open channel flow.
Other DLT 2.0 applications include two-tank inventory where you can monitor level in two tanks with one instrument. The DLT 2.0 will alternate display of level in both tanks plus transmit 4-20mA outputs. Use the built-in relays to activate alarms or level controls. This versatile dual-sensor instrument can also be configured as a submergence alarm for Parshall flumes.
Features
Measures level, differential level and open channel flow
Two non-contacting ultrasonic sensors
Accuracy: ±0.25% of Range or 2 mm (0.08") whichever is greater
Repeatability and Linearity: ±0.1%
Watertight, dust tight NEMA4X (IP66) polycarbonate enclosure
Large white backlit LCD display
Three isolated 4-20mA outputs
Built-in 5-key calibratior
2 programmable control relays
Optional 2 million point data logger
Optional intrinsically safe sensors
What's in the Box
(2) PZ15 ultrasonic sensors with 15 ft. range
(2) 25 ft. coaxial sensor cables
PC software utilities disk
Installation and operation manual