- Air Quality Meter
- Anemometer
- Battery Test Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current Injection Test
- Current-Echosounder
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
HT Instruments T2000 Earth Ground Clamp Meter
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The T2000 is designed for the resistance measurement on earth rods with ground loop method without the disconnecting certain parts of the installation under test.
This type of measurement can be used for evaluation of a single rods’ resistance within an earth installation assuming they do not affect each other.
The inner part of the instrument is made of 2 jaws one for current and one for voltage. The voltage jaw generates a potential (E) on the loop during resistance measurement. A current (I) is consequently generated on the loop and is measured by the current jaws. Based on the value of parameters E and I the instrument displays the resistance value R calculated as their ratio.
The T2000 clamp also performs AC current up to 20A and leakage current with 0.05mA resolution and the setting of alarm thresholds on measurements is possible. The instrument is compliant with IEC/EN61010-1, CAT III 150V and is ideal for simple measurements both in domestic and industrial environments.
Features:
Resistance measurement on earth probes by means of ground loop method
Direct measurement on earth probes without any cable breaking
Measurement of leakage current on earth installations
Setting of alarm thresholds on measurements
Storage of measurement results
Detection of current noise on measurements
Data HOLD function
Backlight
Auto Power OFF
What's in the Box:
(1) Resistive test loop
(1) Carrying case
(1) Batteries
(1) User manual

