Warning: session_start(): open(/var/cpanel/php/sessions/ea-php56/sess_2tgpv1tk1398jckc8lds1pvak2, O_RDWR) failed: Disk quota exceeded (122) in /home/majumpn/public_html/system/library/session.php on line 11Warning: session_start(): Cannot send session cache limiter - headers already sent (output started at /home/majumpn/public_html/index.php:108) in /home/majumpn/public_html/system/library/session.php on line 11Warning: Cannot modify header information - headers already sent by (output started at /home/majumpn/public_html/index.php:108) in /home/majumpn/public_html/index.php on line 181Warning: Cannot modify header information - headers already sent by (output started at /home/majumpn/public_html/index.php:108) in /home/majumpn/public_html/system/library/currency.php on line 45Warning: fopen(/home/majumpn/public_html/system/cache/cache.language.1777702830): failed to open stream: Disk quota exceeded in /home/majumpn/public_html/system/library/cache.php on line 32Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/majumpn/public_html/system/library/cache.php on line 34Warning: fclose() expects parameter 1 to be resource, boolean given in /home/majumpn/public_html/system/library/cache.php on line 36Warning: fopen(/home/majumpn/public_html/system/cache/cache.currency.1777702830): failed to open stream: Disk quota exceeded in /home/majumpn/public_html/system/library/cache.php on line 32Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/majumpn/public_html/system/library/cache.php on line 34Warning: fclose() expects parameter 1 to be resource, boolean given in /home/majumpn/public_html/system/library/cache.php on line 36 CHAUVIN ARNOUX DOX2070B Benchtop Digital Oscilloscope
CHAUVIN ARNOUX DOX2070B Benchtop Digital Oscilloscope

CHAUVIN ARNOUX DOX2070B Benchtop Digital Oscilloscope

Rp. 38,500,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.

Chauvin Arnoux Metrix® [DOX 2070B] 70 MHz, 2-Channel Benchtop Digital Oscilloscope. The METRIX DOX 2000B series oscilloscopes are very easy to use and are housed in a space-saving, shallow-depth enclosure designed especially for laboratory workstations. The large screen includes 16 divisions in the X-axis in full screen display and is individually configurable: normal or luminescent display, YT or XY display, adjustment of colors, screen grid, brightness, contrast, etc. Rotary knobs and illuminated direct function keys on the front panel facilitate operation. The handle makes the oscilloscope easy to transport and the non-slip feet ensure stable placement on the workbench. High performance and a wide range of acquisition and analysis functions: Signal acquisition and analysis is performed at 3 levels, in real time or time equivalent. The acquisition memory has a depth of 32K points and additional memory can be added via a USB pen for optimal analysis. Sensitivity ranges vertically in 12 measurement ranges from 2 mV/div to 10 V/div and horizontally from 5 ns/div to 50 s/div. Advanced functions are available: simple MATH functions + / - / x / ÷ and an FFT function "in real time" with simultaneous display of the curves. Practical PASS/FAIL function: OK/NOK test based on a limiting envelope. The supplied EASYSCOPE software allows the operation of the instrument, tests and the transfer of curve files and screen copies.

Part Number: DOX 2070B
Channel: 2-Channel
Band bandwidths: 70 MHz
Optimised for measuring, monitoring and analysing electrical signals
Vertical sensitivity: 2mV/div to 10V/div in 12 ranges
Two channels
Waveform memory with a maximum capacity of 1 Mpts per channel
Waveform memory extends to 2 Mpts in interlaced mode
Features an extended memory of 2MB
Includes an array of acquisition and analysis modes with advanced trigger functions
20 setups and 20 waveforms are saved to the internal memory
Capable of performing real-time analysis  on two different displays
Includes the mathematical functions: addition, subtraction, multiplication, division and FFT
View up to 32 simultaneous measurements on the display
7”, panoramic, colour LCD screen with an 800 x 480p resolution
A comprehensive selection of timing parameters allow the user to compare signals on two separate channels as well as zoom
Displays measurement results instantly
Pass/ Fail function compares the real-time signal to a pre-defined profile (MASK)
Instantly displays the Pass/ Fail result on the screen
Pass/ Fail function is particularly well suited to monitoring the development of signals according to a specified profile
Record mode may be triggered by a Pass/ Fail test signal
Record mode saves signals
Record mode has a maximum recording length of 2500 frames of 2.5 kpts
Roll and Recorder modes allow the user to monitor slow signals in real time
Roll mode is optimised for time-based ranges of > 100ms
Recorder mode can be used to record slow signals in real time
Recorder mode has a maximum recording depth of 7Mpoints
Auto-calibration mode ensures the accuracy of the CH1 and CH2 acquisition channels
Digital filters prevent high- and low-frequency noise from affecting the trigger
2.5kHz low-pass filter: allows the user to view the fundamental while suppressing the harmonics
2.5kHz high-pass filter: using this filter the user is able to view the edges and suppress low-frequency plateaux
5 Hz FcB and 2.5 kHz FcH band stop filter: for reducing the harmonics
16 horizontal divisions in full-screen mode
Select between a normal and persistent display
Choose either a YT or XY format
Adjust the display’s colours
Alter the graticule, brightness and contrast.
English, French, Spanish, Italian or German language options
Fast start up and shut down times – 10s
Intuitive ‘soft key’ icons allow the user to access and view desired signal types instantly
HOST USB can be used to expand the recording storage capacity
Utilise the USB and RJ45 (Ethernet) ports to facilitate PC communication
Once connected to a PC the Easyscope Software can be used to operate the oscilloscope
Use the Easyscope Software to initiate tests as well as recover trace and screenshot files
Kensington locking system with a security slot for a plug-in padlock 
2GS/s sampling frequency
Cost-effective oscilloscopes with an eclectic array of features

Include:
(1) DOX 2070B - 70 MHz, 2-Channel Benchtop Digital Oscilloscope
(1) European Mains Power Cable
(1) Switchable Voltage Probes with 1/1 and 1/10 Ratios
(1) USB A/B Cable
(1) CD-ROM with PC Easyscope Software and User’s Manual