Categories
- Air Quality Meter
- Anemometer
- Battery Test Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current Injection Test
- Current-Echosounder
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
CHAUVIN ARNOUX CA8436 Power and Energy Quality Analyzer
Rp. 225,000,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
Chauvin Arnoux CA 8436 [P01160595] 1, 3-Phase, 100A AC, 1000 V AC / 1200V DC Power Quality Analyser. The qualistar analyzers are especially suitable for maintenance and testing services in industrial or commercial plants or in public institutions. They provide an immediate mapping of the most important network parameters and the network quality. The devices are handy and accurate and offer many calculation and editing functions in addition. The series of the qualistar + Power Analyzers covers all applications in accordance with IEC 61010 in the measuring categories CAT IV 600 V and 1000 V CAT III. The qualistar C.A 8436 has sealed connections in protection class IP67 and is compatible with the whole existing qualistar measuring accessories. The qualistar devices can be from the simplest to most complex system in all power networks. To increase the operating time can be supplied the C.A 8436, even for the phase conductor of 100 V to 1000 V, AC or DC. The robust construction site case is particularly suitable for use in industrial plants, factories and workshops. In addition to its shock resistance, it is additionally protected against any penetration of liquids.
Features:
Part Number: P01160595
Maximum Current Measurement: 100 A ac, 100 A ac/dc, 200 A ac, 1000 A ac, 1300 A ac/dc, 10000 A acA
Maximum Power Measurement: 10 MW, 10 MVAR, 10 MVAW
Number of Phases: 1, 3
Maximum Voltage : 1000 V ac, 1200V dc
Investigate the quality of an industrial or administrative building’s main electrical network
Five voltage inputs and four current inputs
Supplied with identification rings for colour coding the inputs
Optimised for indoor and outdoor use
IP67
Self-powered by phase from 100V to 1000V AC/DC
Complaint with 600V CAT IV and 1000V CAT III
IEC 61010 compliant
Diagnose electrical installations
Measure voltage, current and power parameters
Determine the energy efficiency of electrical installations
Calculation of distorting power
Calculation of distorting voltages
Calculation of distorting currents
Real-time display of waveforms (four voltages and four currents)
Half-period RMS measurements of voltages and currents
Measure, calculate and display harmonics up to the 50th order
Measure total and per phase P, N, Q1, S and D power values
Total and per phase energy measurement
K factor and FHL calculation
Calculation of cos ɸ displacement power factor (DPF) and the power factor (PF)
Calculation of Pst (short-term flicker measured over ten minutes)
Calculation of Plt flicker values (long-term flicker measured over two hours)
Current and voltage unbalance calculation
Monitor the electrical network with the setting of alarms
Capture, view and record parameters, transients, alarms and waveforms simultaneously
Measurements are displayed in real-time
Wide, colour, TFT display
View a phasor diagram
Direct, quick access to the main measurements such as harmonics and flicker
Direct, quick access to measurement functions
Inrush function: measure the maximum input current draw of the connected electrical item over a period of ten minutes
Inrush function can be used to size the electrical installation and to view the source of switching faults
Flicker function
Energy function
Selectable energy units: kW, Joule, nuclear-toe, non-nuclear toe and BTU
K-factor function: compliant with NF EN 50464-3
K-factor function can be used to ascertain a transformer’s derating
Simultaneously records and measures FHL and European K factor parameters
Harmonics function
Harmonics can be calculated in %f and %r
Determine the decomposition of the harmonics of the neutral conductor
Determine distorting voltages and currents
Harmonics mode measures global THD, U, I, V , VA and phase offset
Distorting Power function
Measure deforming power (D) for sizing the anti-harmonic filters
Measure reactive power (Q1) linked to the phase shift of the fundamental, this can be used to size the capacitor bank facilitating power phase correction
Determine installation’s total reactive power (N)
Alarm mode: configure up to forty alarms
Alarm breaches are recorded with the date and time
Recording mode
Record over 450 values with parameters and graphic displays
Automatically indicates the min and max values
Transient mode: capture hundreds of transients spanning several tens of µs
Can be used in several modes simultaneously
View data for measurement campaigns in real-time
Export information to a PC via a USB connection
Use with the included software to communicate with a PC in real-time
Record and export data to the software
Capture screenshots of the display
Screenshots are saved to the analyser’s memory with a date and time
Screenshot and Help functions are accessible via the front panel
The Help function can be accessed at any point of the measurement process
Intuitive, easy-to-use, multilingual menu
Configure the analyser’s date, time, network and display colour and contrast
Recognises current sensors automatically
Automatically sets the parameters for EN50160 reports
Integrated DC components
Foldaway stand
A comprehensive, adaptable, easy-to-use and robust power quality analyser
Suitable for indoor and outdoor industrial settings
Include:
(1) CA8436 - Qualistar+ Power Quality Analyser
(1) Carry Bag
(1) USB Cable
(1) IP67 Mains Power Cable
(5) 3m Black IP67 BB196 Banana Leads
(5) Lockable Crocodile Clips
(1) 12-colour Identification Kit
(1) Scratch-proof Screen Protection Film (mounted)
(1) Safety Datasheet
(1) Multilingual Operating Manual on CD
(1) PC Data Retrieval Software on CD

