- Air Quality Meter
- Anemometer
- Battery Test Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current Injection Test
- Current-Echosounder
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
PALMER WAHL TC622A Pocket RTD Calibrator
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
User friendly and robust, the New Wahl TC Series Pocket Calibrators are designed to simplify temperature transmitters and probes maintenance and commissioning. They feature 0.02% Accuracy and measure and simulate Thermocouples or RTD’s. Resolution is programmable for better reading by user with up to 1mΩ or 1uV.
Simulation Function
Simple and Cyclical Ramps: Ramps can be generated by setting high and low values, rising and falling times, and stabilization and delay times. Delay time (programmable between 1 to 3600 seconds) allows a single user to launch ramp and go to the control panel.
Synthesizer Mode: This mode allows sending of predefined values with programmable frequency.
Steps Mode: This mode allows sending of values with programmable amplitude and frequency.
Scaling: This operation allows correction of probe errors. Scaling is performed using up to 10 segments, in order to fit with the real calibrated value
Measurement Functions
Calibrated Sensors: A database can be created to design curves for sensors after calibration in relation with the corrections shown on a calibration report.
Scaling: This operation allows correction of probe errors. Scaling is performed using up to 10 segments, in order to fit with the real calibrated value.
Data Recording: Data is recorded whether manually on event or automatically with programmed frequency. Data is time stamped, and can be displayed as list or curves.
In The Box
Protective Boot
4 AA Batteries
User Manual
Wrist Strap
2 Measurement Leads
Carrying Case