GILL Instruments MetPak RG (1723-3A-2-111) Weather Station

GILL Instruments MetPak RG (1723-3A-2-111) Weather Station

Rp. 115,000,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.

The design of the MetPak RG allows all measurements to be as accurate as possible without influencing other measured parameters yet provides a complete, compact, reference quality system. In addition to the rain gauge parameter the MetPak RG utilises the Gill WindSonic ultrasonic technology to measure wind speed and direction and a highly accurate barometric pressure sensor is housed within a vented enclosure. Temperature and humidity are measured using a Rotronic Hygroclip HC2-S3 temperature/humidity probe contained in a naturally aspirated radiation shield. The unit is especially suitable for harsh or marine environments. The MetPak RG weather station is supplied with digital SDI-12, RS232 & 422 outputs. The serial data output is ideal for interfacing with a WS-15A Display Unit. Data from the MetPak RG can be stored using the SpaceLogger.W10 (WindLogger) and SpaceLogger.W8.Wireless data loggers providing a compact affordable logging solution for long term data collection. Low power consumption enables this weather station instrument to be used in remote locations where power is at a premium.An electrical junction box is fitted to the mounting bracket allowing convenient termination of all electrical cables

Wind Speed & Direction
Temperature
Humidity
Barometric Pressure
Dew Point
Precipitation
SDI -12 Output
Gill ASCII Output

Specifications:
Wind Measurement: Sensor: WindSonic ultrasonic; Parameters: Polar Wind Speed & Direction or U & V Vectors
Wind Speed: Range: 0-60m/s (134 mph); Accuracy: ± 2% @12m/s; Resolution: 0.01 m/s (0.02 mph): Threshold: 0.01 m/s (0.02 mph); Units of measure:m/s, knots, mph, kph, ft/min
Wind Direction: Range:0 to 359 degrees – no dead band; Accuracy: ± 3° @12m/s; Resolution: 1°
Air Temperature: Sensor: Rotronic HygroClip model HC2-S3; Sensor type: Pt100 1/3 Class ; Range: -35°C to +70°C; Accuracy: ± 0.1°C; Resolution: 0.1°C (0.1°F): Units of measure: °C, °F or K.
Relative Humidity: Sensor: Rotronic HygroClip model HC2-S3. Compensated for temperature dependency; Range: 0-100% RH; Accuracy: ± 0.8% @23°C; Resolution: 0.1% RH; Units of measure: % RH
Barometric Pressure: Sensor: Solid state device. Compensated for temperature dependency -20°C to +70°C; Range: 600-1100hPa; Accuracy: ±0.5hPa; Resolution: 0.1hPa; Units of measure: hPa, mbar, mmHg, InHg
Precipitation: Measurement Concept: Aerodynamic tipping bucket rain gauge; Range: Effectively unlimited; Resolution: 0.2mm; Units of Measure: mm per tip.
Dew Point: Sensor: Rotronic HygroClip model HC2-S3; Accuracy: ± 0.15°C @ 23°C ambient temp, 20°C dew point; Resolution: 0.1°C (0.1°F); Units of measure: °C, °F or K.
Outputs: Digital outputs: RS232, RS422 or SDI-12; Baud rates:  200 (SDI-12) – 4800-57600 (ASCII RS232, RS422); Protocols: ASCII or SDI-12 V1.3; Data output: 1Hz, 2Hz, 4Hz or polled mode Mechanical; External construction: UV stabilised white thermoplastic
Mechanical: External construction: UV stabilised white thermoplastic; Mounting: Pole Mounting:Gloss white painted aluminium mounting bracket (with moulded plastic V-block and stainless steel U-bolt), which allows it to be attached to a vertical pipe of any diameter between 25mm and 50mm. Weight: 2.1kg (including bracket); Radiation shield: 6-plate, naturally aspirated
Power Supply: Supply voltage: 5V to 30 V dc; Current: <16mA (Output 1 second) @ 12 V
Power Supply: SDI-12; Supply voltage; 12V nominal (9.6 – 16V); Current; < 6.5MA low power operation
Environmental: Protection class: IP65; Operating temperature: -35°C to +70 °C; Storage temperature: -40°C to +80 °C; Operating humidity: 0% to 100% humidity Miscellaneous; Calibration;Factory calibrated
Miscellaneous: Calibration: Factory calibrated; Software: MetView - free software providing the means for configuring the MetPak II and reading output data.