- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Power Supply
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
GILL Instruments MetPak (1723-2B-2-111) Weather Station
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The MetPak is a compact and lightweight multi-sensor instrument that measures a wide range of weather parameters. Ultrasonic technology, as used in the proven WindSonic instrument, measures wind speed and direction. Temperature and humidity are measured using industry standard probes housed in a naturally aspirated radiation shield. Barometric pressure is measured within a vented enclosure. The serial data output is ideal for interfacing with a WS-15A Display Unit or for data logging to a SpaceLogger®WindLogger.
The MetPak™ weather station can be supplied with digital SDI-12, RS232 & 422 outputs. Low power consumption enables this weather station instrument to be used in remote locations where power is at a premium. An electrical junction box is fitted to the mounting bracket allowing convenient termination of all electrical cables
Wind Speed & Direction
Barometric Pressure
Temperature
Dew Point
Humidity
Rugged, Professional Design
Specifications:
Wind Measurement
Sensor: WindSonic ultrasonic; Parameters: Polar Wind Speed & Direction or U & V Vectors; Wind Speed:Range: 0-60m/s (134 mph); Accuracy: ± 2% @12m/s; Resolution: 0.01 m/s (0.02 mph); Threshold: 0.01 m/s (0.02 mph);Units: of measure m/s, knots, mph, kph, ft/min
Wind Direction: Range: 0 to 359 degrees–no dead band;Accuracy: ± 3° @12m/s;Resolution:1°; Air Temperature: Sensor: Rotronic HygroClip model HC2-S3; Sensor type: Pt100 1/3 Class B; Range:-35°C to +70°C; Accuracy: ± 0.1°C; Resolution: 0.1°C (0.1°F); Units of measure:°C,°F or K;
Relative Humidity: Sensor: Rotronic HygroClip model HC2-S3.Compensated for temperaturedependency; Range:0-100% RH; Accuracy:± 0.8% @23°C; Resolution:0.1% RH; Units of measure: % RH
Barometric PressureL: Sensor: Solid state device.Compensated for temperature dependency-20°C to +70°C; Range: 600-1100hPa; Accuracy: ±0.5hPa; Resolution: 0.1hPa; Units of measure: hPa, mbar, mmHg, InHg; Dew Point Sensor: Rotronic HygroClip model HC2-S3; Accuracy:± 0.15°C@ 23°C ambient temp, 20°C dew point:Resolution: 0.1°C (0.1°F); Units of measure:°C,°F or K
Outputs: Digital outputs: RS232, RS422 or SDI-12; Baud rates: 1200 (SDI-12)–9600-57600 (ASCII RS232, RS422); Protocols: ASCII or SDI-12 V1.3; Data output: 0.25, 0.5, 1 Hz or polled mode MetPak II statusStatus codes provided within the data message string; Mechanical: External construction: UV stabilised white thermoplastic
Mounting: Pole Mounting: Gloss white painted aluminium mounting bracket (with mouldedplastic V-block and stainless steel U-bolt), which allows it to beattached to a vertical pipe of any diameter between 25mm and 50mm
Weight: 1.1kg (including bracket); Radiation shield: 6-plate, naturally aspirated
Power Supply: Supply: voltage: 5V to 30 V dc; Current: <50mA;
Environmental: Protection class:IP65; Operating temperature:-35°C to +70 °C; Storage temperature:-40°C to +80 °C: Operating humidity: 0% to 100% humidity; Miscellaneous: Calibration: Factory calibrated
Software: MetView-free software providing the means for configuring theMetPak II and reading output data
Includes:
(1) Gill Instruments MetPak™ Weather Station
(1) MetSet configuration software
(1) MetView data logging/visualisation software
(1) Mounting kit to adapt to poles or masts
(1) Selectable ASCII, NMEA, SDI-12 or Modbus Outputs

