- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Power Supply
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
HANNA HI9126 Calibration Check Portable pH/ ORP Meter
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The HI 9126 includes HANNA‘ s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode, Calibration Check™ warns users that maintenance may be needed.
Calibrated buffers are continuously displayed in measurement mode to remind users of the instrument’ s calibration point. Users can easily determine if readings are taken too far outside the calibration range.
The HI 9126 can store and recall readings at the touch of a button.
HI 9126 utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for consistently accurate results. The HI 9126 can also measure ORP using optional probes.
Features:
pH Calibration Check™
Electrode condition monitoring
Measurement store and recall
Backlit, multi-level LCD display
Real time clock
User-selectable calibration reminder
Tutorial messages displayed on LCD
BEPS; ( Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.
Battery % displayed on startup.
Specification
Range pH -2.00 to 16.00 pH
ORP ±699.9 mV; ±1999 mV
Temperature -20.0 to 120.0°C / -4.0°F to 248.0°F
Resolution pH 0.01 pH
ORP 0.1 mV; 1 mV
Temperature 0.1°C / 0.1 °F
Accuracy @ 20°C pH ±0.01 pH
ORP ±0.2 mV; ±1 mV
Temperature ±0.4°C/±0.8°F (excluding probe error)
pH Calibration
Check yes, check of the electrode status during calibration
Calibration pH automatic, one or two point with seven memorized buffer values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers
Offset ±1 pH
Slope from 80 to 108%
Temperature
Compensation automatic or manual, -20 to 120°C (-4 to 248°F) without temperature probe
pH Electrode HI 1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included)
Input Impedance 1012 Ohms
Battery Type / Life 1.5V (3) AAA / approximately 200 hours of continuous use without backlight (50 hours with backlight). auto-off after 20 minutes of non-use (can be disabled)
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)
Weight 300 g (10.6 oz.)