Categories
- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Power Supply
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
PCE TDS200M Portable Ultrasonic Flow Meter
Rp. 145,000,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
Highlights
- Measuring range ±32 m/s
- USB-C interface for data transfer
- Optional software for analysing the measured values
- Reproducibility ±0.5 % of measured value
- Heat quantity measurement
- Data memory for 10 million measuring points
- individually adjustable alarm limits
- optionally with ISO or DAkkS calibration certificate
Specification
Flow measurement
Measuring range ±32 m/s
Accuracy 0,001 m/s
Genauigkeit DN ≥50 mm: ±1.5 % rdg. for velocities > 0.3 m/s
DN <50 mm: ±3.5 % rdg. for velocities > 0.3 m/s
Reproducibility ±0.5 % of measured value
PCE-TDS 200 M SENSOR Sensor pair
Pipe diameter DN 50 ... 700 / 57 ... 720 mm
Temperature resistance -30 ... 160 °C
Measuring method Z, V, N, W
Medium - water
- sea water
- oil
- crude oil
- methanol
- ethanol
- diesel
- petrol
- petroleum
- user defined
(manual input of the sound velocity from the medium)
All liquids with an impurity <5 %
Pipe material - copper CU
- steel FE
- stainless steel VA
- aluminium AL
- brass ME
- cast iron CI
- iron FE
- nickel NI
- titanium TI
- zink ZI
- acrylic AC
- polyethylene PE
- polypropylene PP
- polyvinyl chloride PVC
- nylon NY
- user defined
(manual input of the transversal sound velocity
of the pipe material)
Inner pipe lining - no lining
- user defined
- epoxy resin
- rubber
- mortar
- polystyrene PS
- polyethylene PE
- polytetrafluoroethylene PTFE
- polyurethane PU
- polypropylene PP
- user defined
(manual input of the longitudinal sound velocity
of the inner lining of the pipe)
Measurement parameters flow velocity, volume flow and volume
Units (dimensions) mm, in
Units (flow velocity) m/s, ft/s
Units (volume flow) m³, l, gal, igl, mgl, cf, bal, ib, ob
Time specification seconds, minutes, hours, days
Units (volume) m³, l, gal, igl, mgl, cf, bal, ib, ob
Further specifications
2.8" LCD 2,8“ LCD
Menu metrisch / imperial
Menu languages German, English, French, Spanish,
Italian, Dutch, Portuguese, Danish, Turkish, Polish, German
Turkish, Polish, Russian, Chinese, Japanese
Operating and storage conditions Temperature: -20 ... +65 °C
Humidity: 10 ... 95 % r. h., non-condensing
Data logger 32 GB memory capacity / 10 million measuring points
Unterface USB (for online measurement, readout of the internal memory
memory and for recharging the battery)
Protection class IP52
Power supply Internal Internal: LiPo battery (3.7 V, 2500 mAh)
External: USB 5 VDC, 500 mA
Operating time approx. 10 h
Dimensions 165 x 85 x 32 mm
Weight 255 g
Delivery Scope
1 x Ultrasonic flow meter PCE-TDS 200 M
1 x flow sensor PCE-TDS 200 M SENSOR (pair)
2 x 5 m connection cable
2 x detachable cable ties
1 x power supply unit
1 x USB-C cable
1 x ultrasonic contact gel
1 x PCE measuring tape
1 x plastic case
1 x instruction manual