- Air Quality Meter
- Anemometer
- Battery Test Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current Injection Test
- Current-Echosounder
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
HANNA HI2315 Conductivity Benchtop Meter
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The HI 2315 Bench-Top Conductivity Meter is a multi-range meter with built-in automatic temperature compensation for testing Conductivity. The HI 2315 replaces EC 215 and features a large, easy to read LCD,
solution holders and an attractive redesigned case.
The HI 2315 utilizes a four ring potentiometric probe with platinum sensor that offers greater versatility and accuracy over amperometric designs.
A potentiometric probe works on the principal of induction which eliminates the effects of polarization (a common problem of amperometric systems). Two outer rings apply an alternating voltage and induce a
current loop in the solution while two inner rings measure the voltage drop induced by the current loop (which is dependent on the conductivity of the solution). By utilizing the 4-ring method, it is possible to measure
very low to high conductivity levels (up to 200 mS/cm) without changing probes.
FEATURES/BENEFITS
* Four ring potentiometric platinum probe
* Four measurement ranges
* ±1% F.s. accuracy
* Manual calibration
* Automatic Temperature Compensation
* Large LCD
* Built-in Solution Holders
FEATURES IN DEPTH
Four ring probe - This allows for 1 probe to measure 4 ranges with no polarization effect. It provides an increased accuracy (1% F.S.) over amperometric style meters.
Manual calibration - This simple to use feature allows the HI2315 Bench-Top Conductivity Meter to be calibrated to any value within the measurement ranges (0.0 to 199.9 µs/cm; 0 to 1999 µs/cm; 0.00 to 19.99
ms/cm; 0.0 to 199.9 ms/cm) It is also less expensive than models with auto-calibration
Manual adjustable temperature correction coefficient (ß = Beta) - This simple to use feature allows for different temperature correction coefficients to be used based on the sample being tested. It is adjustable from
0-2.5%/°C.
Automatic Temperature Compensation - This helps provide the HI 2315 with higher accuracy since conductivity is very sensitive to temperature variations.
Large LCD - The new, larger LCD is bright and easy to read.
Built-in Solution Holders - The HI 2315 has solution holders built into the casing. This convenient feature saves space and prevents solutions from tipping over.
Recessed Connector Bay - Protects connectors from liquids.
SPECIFICATIONS
Range 0.0 to 199.9 µs/cm; 0 to 1999 µs/cm; 0.00 to 19.99 ms/cm; 0.0 to 199.9 mS/cm
Resolution 0.1 µs/cm; 1 µs/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy (@20°C/68°F) ±1% F.s. (excluding probe error)
Calibration Manual, one point
Temperature Compensation Automatic, 0 to 50°C (32 to 122°F)with ß adjustable from 0 to 2.5%/°C
Probe HI 76303, platinum four ring conductivity probe with internal temperature sensor, Din connector and 1 m (3.3') cable (included)
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing