- Air Quality Meter
- Anemometer
- Battery Test Analyzer
- Calibration Tester
- Chart Data Recorder
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current Injection Test
- Current-Echosounder
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Oscilloscopes
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Weather Station
- Wood Moisture Meter
FLUKE 9102S Temperature Calibrator
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
For work in the temperature range of -10°C to 122°C, Fluke Calibration Model 9102S dry-well is another first in the industry, featuring stability to ±0.05°C.This dry-well is only four inches high and six inches wide, achieves temperatures as low as -10°C, includes a NIST-traceable calibration, and is stable to ±0.05°C. The Fluke Calibration 9102S is excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient.The 9102S has two wells so you can use one for a reference thermometer to increase accuracy. Both wells are 1/2 inch in diameter, and each has inserts available for almost any sensor size. The 9102S also has a battery pack option that gives you approximately four hours of field use when AC power is unavailable.
Features:
Excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient
Has two wells so you can use one for a reference thermometer to increase accuracy
Optional inserts are available for almost any sensor size
Smallest dry-wells in the world
Ranges from -10°C to 375°C
Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
RS-232 interface with Hart software Model 9930
What's in the Box:
(1) Manufacturer's NIST-Traceable Certificate
(1) Instruction