RADIODETECTION RD7100PLG (Power Industry) with TX5 Cable and Pipe Locator

RADIODETECTION RD7100PLG (Power Industry) with TX5 Cable and Pipe Locator

Rp. 148,500,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.

Accurately locating and marking buried assets ensures minimum downtime during repair or maintenance activities. It also prevents damage which can be costly for both you and your customers.
The RD7100 (successor to the RD7000) range offers the power of Radiodetection’s most advanced locating technologies, with each model optimized for a specific industry. Users benefit from the simplicity of having menu options and capabilities matched to their requirements.
The GPS and usage logging models are designed to facilitate the observance of best working practices amongst remote crews.

Applications:
RD7100SL - Construction Industry
Accurate and simple to use, the RD7100SL comes with four active and two passive frequencies that cover the majority of site locating tasks. A rugged, IP65 rated casing along with a high contrast screen make it suitable for use in all weather conditions.

RD7100DL(G) - Water Industry
With four sonde frequencies, the RD7100DL can be used to trace deep pipes made from a variety of materials including: cast iron, clay, concrete and brick. Additionally, it can be used to locate Cathodic Protection System (CPS) signals applied to pipelines.

RD7100PL(G) - Power Industry
Designed for use in dense infrastructures where signals from high voltage equipment and cables can be confusing or overwhelming. Dynamic Overload Protection reduces the effect of interference, while Power Filters™ can be used to establish if a large power signal comes from one source or from the presence of multiple cables.

RD7000TL(G) - Telecom Industry
RD7000TL features higher frequencies to locate high impedance cables amongst large bundled pairs and sonde frequencies for duct and conduit tracing. Higher frequencies can also be used to trace sheathed domestic cables without grounding connections. Cable sheath faults can be located to within 100mm using 8kHz Fault Find mode with a Radiodetection A-Frame.

Specifications:
Sensitivity: 6E-15 Tesla, 5μA at 1 meter (33kHz)
Dynamic range: 140dB rms/√Hz
Selectivity: 120dB/Hz
Depth measurement precision1: ± 3%
Locate accuracy: ± 5% of depth
Active Locate filter bandwidth: ± 3Hz, 0 < 1kHz; ± 10Hz, ≥ 1kHz
Start-up time: Less than 1 second
Metric: Cable / Pipe: 30m Sonde: 19.5m, Imperial: Cable / Pipe: 98' Sonde: 64'
Active Locate Modes: Up to four, model dependent:  Peak;Peak+™ (choice of combined Peak & Guidance or Peak & Null); Guidance; Null
Gain control: Guidance Mode: Automatic. Other modes: Manual gain using “+” or “-” with one touch to return to center (50% of Full Scale)
Option selection: All options can be enabled or disabled on the locator or using the RD Manager PC software
Languages supported: Fourteen: English, French, German, Dutch, Polish, Czech, Slovakian, Spanish, Portuguese, Swedish,Italian, Turkish, Russian, Hungarian
Mains power network options: 50 Hz or 60 Hz
Mode selection: All locate modes with the exception of Peak Mode can be individually enabled or disabled
Active frequency selection: All active frequencies available can be individually enabled or disabled
Passive mode selection: All passive modes can be individually enabled or disabled
StrikeAlert: Enable / disable
Peak+ arrow selection: Guidance arrows or Null arrows; Selected using the locator menu or with a long press of the antenna key
GNSS (‘GPS’) settings: Internal / Off / Reset. SBAS On / Off
Time / date setting: Correct or update locator real-time clock using the RD Manager PC software or GNSS signals
(GPS/Logging enabled units)
Wired connections: Mini-USB: Connect to a PC to configure and update locator, and to retrieve usage log and survey
measurement data. 3.5mm Stereo jack: Connect wired headphones. Accessory port: Connect Radiodetection accessories
Alkaline battery options: 2 × D-Cell (MN1300 / LR20) alkaline batteries (standard)
Rechargeable battery options: Custom Lithium-Ion (Li-Ion) battery pack; 2 × D-Cell (MN1300 / LR20) Nickel Metal Hydride (NiMH) batteries
Battery run-time (continuous)4: Li-Ion pack: 35 hours; 2 × Alkaline D-Cells 13 hours
Battery chemistry identification: Lithium-Ion pack: Automatic sensing; NiMH / Alkaline: Software switchable
Charging options (Li-Ion pack): Mains charger: 100-250 Volts AC, 50/60 Hz; Automotive charger: 12-24V DC
Charging time (Li-Ion pack): 3 hours to 80% from empty with maintenance trickle charging thereafter
Design: Ergonomic, balanced and lightweight design for comfortable use during extended surveys
Construction: Injection Molded ABS Plastic
Weight: With Lithium-Ion battery pack fitted: Metric: 1.8kg, Imperial: 4.0lb; With D-cell alkaline batteries fitted:
Metric: 1.9kg, Imperial: 4.2lb
Ingress Protection rating: IP65. Protected against dust ingress and jets of water5 applied from any direction
Display type: High contrast custom made monochrome LCD
Audio options: Built-in waterproofed speaker. 3.5mm headphone socket
Operating temperature6: Metric: -20 to 50°C, Imperial: 14 to 122°F
Storage temperature: Metric: -20 to 70°C, Imperial: 14 to 158°F
Unit dimensions: Metric: 648mm × 286mm × 125mm, Imperial: 25.5" × 11.3" × 4.9"
Shipping dimensions: Metric: 700mm x 260mm × 330mm, Imperial: 27.6" x 10.2" x 13"
Shipping weight (with batteries fitted): Metric: 2.6kg, Imperial: 5.7lb
Operating System Compatibility: Microsoft® Windows® XP, 7, 8, 8.1, 32 and 64-bit versions