One of the most popular multifunction testers (also known as MFTs or installation testers) on the market today, the Fluke 1651B is rugged, reliable and makes testing electrical parameters as simple as possible.

Part of Fluke's 1650B series, the original 1651 went through a redesign by Fluke to further expand upon the functionality of the original tester and create a better instrument than ever before. This multifunction tester is packed full of advanced functionality and testing procedures and is perfect for any electrician.

All-In-One Testing
Don't constantly swap testers when checking electrical installations - the Fluke 1651B contains all of the testing functions you need in one instrument in order to verify the safety of electrical installations in domestic, commercial and industrial applications.

Accessing testing procedures is as simple as turning the rotary dial on the front of the tester. The Fluke 1651B installation tester is capable of testing voltage, frequency, insulation, continuity, performing fast high current loop testing, loop testing with non trip mode, short circuit current (PSC, PEFC and IK), RCD trip TimeTest, variable RCD and can also be used to test S-type time delayed RCDs.

If you need even more testing procedures the upgraded version of this tester, the Fluke 1652C and Fluke 1653B include more than the entry-level 1651B does.

Test Safely with the 1651B
Don't worry when testing - the Fluke 1651B is built to enhance safety and ensure that any professional using the MFT can carry out their procedures comfortably.

A built-in Earth Volt Touchpad has been designed by Fluke to detect raised earth voltage at a threshold of more than 50V, instantly alerting the user to spikes in voltage that may pose a danger.

The 1651B also ships as standard with a set of Fluke's uniquely designed SureGrip test leads and clips. These are designed to sit more comfortably in the hand and reduce slips and accidental drops when your hands may be slippery or when you're wearing protective gloves.

Fluke 1651B Multifunction Installation Tester Key Features
Large size LCD screen with dual display - ensures you can always clearly see your testing results. Screen is even easy to see when the tester is held around the neck on the supplied strap when carrying out hands-free testing
High current loop mode with non-trip mode for RCD
Unique zero adapter ensures test lead compensation is always correct
Fast voltage measurements between L-N, L-PE and N-PE using mains cord
Rotary dial gives easy access to most functions
Earth volt touchpad detects raised earth voltages of >50V
Backlit LCD display
PASS/FAIL indicators of RCD results
Variable RCD current mode
Rugged enough to withstand a drop of 1m
Voltage and frequency measurements
Insulation and continuity measurements
Loop test non trip mode function
Short circuit current function (PSC, PEFC, IK)
RCD FI Trip TimeTest function
Compliant with IEC 60364, HD 384 and BS 7671 17th edition wiring regs
Full List of Products In Kit:

Fluke 1651B Multifunction Installation Tester
6 AA Cell Batteries
C1600 Hard Carrying Case
Zero Adapter
Mains Test Cord
TL165/UK Fused Test Lead Set
Padded Carrying Strap
Quick Reference Guide
Users Manual on CD-ROM

Specifications
AC Voltage Measurement    
Range:     500 V
Resolution:     0.1 V
Accuracy (50 - 60 Hz)     ± (0.8% + 3 digits)
Input Impedance     3.3 MΩ
Overload Protection     660 Vrms
Continuity Testing    
Range (autoranging):     20 Ω, 200 Ω, 2000 Ω
Resolution:     0.01 Ω, 0.1 Ω, 1 Ω
Test Current:     > 200 mA
Open Circuit Voltage:     > 4 V
Accuracy:     ± (1.5%+3 digits)
Insulation Resistance Measurement    
Test Voltage:     
Fluke 1651B:     250 - 500 - 1000 V
Fluke 1652B:     250 - 500 - 1000 V
Fluke 1653B:     50 - 100 - 250 - 500 - 1000 V
      
Test Voltage:     50 V
Test Current:     1 mA @ 50 kΩ
Insulation Range:     10 kΩ - 50 мΩ
Resolution:     0.01 мΩ
Accuracy:     ± (3% + 3 digits)
      
Test Voltage:     100 V
Test Current:     1 mA @ 100 kΩ
Range/Resolution:     20 MΩ/0.01 MΩ
Range/Resolution:     100 MΩ/0.1 MΩ
Accuracy:     ± (3% + 3 digits)
      
Test Voltage:     250 V
Test Current:     1 mA @ 250 kΩ
Range/Resolution:     20 MΩ/0.01 MΩ
Range/Resolution:     200 MΩ/0.1 MΩ
Accuracy:     ± (1.5% + 3 digits)
      
Test Voltage:     500 V
Test Current:     1 mA @ 500 kΩ
Range/Resolution:     20 MΩ/0.01 MΩ
Range/Resolution:     200 MΩ/0.1 MΩ
Accuracy:     ± (1.5% + 3 digits)
Range/Resolution:     500 MΩ/1 MΩ
Accuracy:     10%
      
Test Voltage:     1000 V
Test Current:     1 mA @ 1 MΩ
Range/Resolution:     20 MΩ/0.01 MΩ
Range/Resolution:     200 MΩ/0.1 MΩ
Accuracy:     ± (1.5% + 3 digits)
Range/Resolution:     500 MΩ/1 MΩ
Accuracy:     10%
      
Auto Discharge:     Discharge time constant, 0.5 second for C = 1 µF or less
Live Circuit Detection:     Inhibits test if terminal voltage > 30 V prior to initiation of test
Maximum Capacitive Load:     Operable with the 5 µF load
Loop Impedance Measurement (High Current Mode and Non-Trip Mode)    
Range:     100 - 500 VAC (50/60 Hz)
Input connection:     Soft Key selection
Loop impedance:     Phase to earth
Line impedance:     Phase to neutral
Limit on consecutive tests:     Automatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical)

Max. Test Current High Current Mode:     
Non-Trip Mode:     

Range/Resolution:     20 Ω/0.01 Ω
Range/Resolution:     200 Ω/0.1 Ω
Range/Resolution:     2000 Ω/1 Ω

 
Accuracy (no Trip mode):     ± (3% + 6 digits)
Accuracy (Hi Current mode):     ± (2% + 4 digits)
PFC, PSC Test    
Computation:     PFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance
Range:     0 - 25 kA
Resolution (Ik < 1000 A):     1 A
Resolution (Ik >= 1000 A):     0.1 kA
Accuracy:     Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing ¹    
Fluke 1651B     AC, G, S
Fluke 1652B     AC, G, S, A
Fluke 1653B     AC, G, S, A
Tripping Time Test (?T)    
Trip Time Accuracy     ±(1% Reading + 1 digit)

Multiplier:     x ½
Current Settings:     10, 30, 100, 300, 500, 1000 mA
Current Accuracy:     +0% - 10%
RCD Type ¹:     G
Measurement Range:     310 ms (Europe), 2000 ms (UK)
RCD Type ¹:     S
Measurement Range:     510 ms (Europe), 2000 ms (UK)

Multiplier     x 1
Current Settings:     10, 30, 100, 300, 500, 1000 mA
Current Accuracy:     +10% - 0%
RCD Type ¹:     G
Measurement Range:     310 ms
RCD Type ¹:     S
Measurement Range:     510 ms

Multiplier:     x 5
Current Settings:     10, 30 mA
Current Accuracy:     ±10%
RCD Type ¹:     G
Measurement Range:     50 ms
RCD Type ¹:     S
Measurement Range:     160 ms
Tripping Current (ramp) Test - Fluke 1652B, Fluke 1653B    
Current Range:     50% - 110% of RCD's rated current
Step Size:     10% of IΔN
Dwell time (Type G): ¹     300 ms / step
Dwell time (Type S): ¹     500 ms / step
Trip Current Measurement Accuracy:     ±5%
Earth Resistance Test (RE) - Fluke 1653B    
Range/Resolution:     200 Ω/0.1 Ω
Accuracy:     ±(2% + 5 digits)
Range/Resolution:     2000 Ω/1 Ω
Accuracy:     ±(3.5% + 10 digits)
Frequency:     128 Hz
Compliance Voltage:     +25 V
Phase Sequence Indication - Fluke 1653B    
Icon:     Icon Phase Sequence indicator is active
Display of Phase Sequence:     

 Displays ‘1-2-3’ in digital display field for correct sequence.

 Displays ‘3-2-1’ for incorrect phase.

 Dashes in place of a number indicate a valid determination could not be made.
¹ RCD Types    
G     General, no delay
S     Time delay
A     Responds to pulsed signal
AC     Responds to AC
Environmental Specifications
Operating Temperature    

 -10 °C to 40 °C
Humidity (Without Condensation)    
10 to 30 °C:     95%
30 to 40 °C:     75%
Safety Specifications
Safety Rating    

 EN 61010-I CAT III 500V, CAT IV 300V
Mechanical & General Specifications
Size    
(L x W x H):     10 x 25 x 12.5 cm
Weight    

 1.17 kg
Batteries    
Type AA:     6
Warranty    

 3 years
Battery type    

 Alkaline supplied, usable with 1.2V NiCD or NiMH rechargeable batteries