- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Water Sampler
- Weather Station
- Wood Moisture Meter
MEGGER DET4TC2 Digital Earth Ground Tester
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
Features:
Extended test range to 200 kΩ
User selectable test frequency and voltage
2, 3 and 4 point testing at the turn of a switch
Attached Rod Technique (ART) enabled
Stakeless measurements enabled
Simple one button operation
Automatic circuit checking
Backlit display
Weather and dust proof to IP54
Complete with lead and stakes packed in a hard wearing carry case
Delivered with a FREE calibration certificate
The DETATC2 is a Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity, attached rod technique, and stakeless measurement capability.
The DET4TC2 includes a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection . They also provide stakeless testing capability. This method allows the operator to use the instrument like a clamp-on ground tester in applications where that method is viable, while also being able to operate as a fall of potential tester if required.
All models are rated to IP54, making them truly outdoor instruments. They are designed to meet stringent safety standards and are rated CAT IV 100 V. The ground testers have been designed to be easy to use – a large selector switch makes selection of 2, 3 or 4 pole tests easy with gloved hands – and the design makes the fitting of shorting links to perform 2-pole tests a thing of the past. A large, clear, easy to read LCD and thumb sized test button also make the instruments particularly well suited to the outdoor conditions of ground testing. In addition to this ease of use feature, the instruments automatically check the connection and conditions of the P spike, C spike, and also the level of ground noise, indicating the status on the display. They also include a voltmeter to enable measurement of ground voltage.
Includes:
Hard Carrying Case
Stake and Wire Kit
Specifications:
Resistance range: 0.01Ω to 200kΩ autoranging
Analog model: 2.5% of scale length
Digital models; 2P measurements 2% ±3 digits; 3P measurements 2% ±3 digits; 4P measurements 2% ±3 digits; ART measurements 5% ±3 digits; Stakeless measurements 7% ±3 digits
Maximum probe resistance: Rp limit: 100k½ (50V output voltage); Rc limit: 100k½ (50V output voltage); Limits reduced to 50k½ for 25V output voltage; Limits reduced to 5k½ for 0.01 ½ resolution
Earth voltage range: 0 – 100 V
Earth voltage accuracy: 2% ±2 V
2-wire test: Yes, all models
3-wire test : Yes, all models
4-wire test : DET4TD, DET4TC2, DET4TCR2
ART (Attached Rod Technique): DET3TC, DET4TC2 and DET4TCR2
Ground current range (with current measuring clamp): 0.5 mA to 19.9 A
Ground current accuracy: 5% ±3 digits
Display: LCD (moving coil meter for analog model)
Test frequency: 128 Hz
Test voltage: 25 V or 50 V, user selectable (factory setting 50 V)
Test current: 450 micro-amps at 25 V or 50 V (selectable), 4.5mA at 25 V
Noise rejection 40V pk to pk
Noise check Automatic (by selector switch DET3TA)
C spike check Automatic (by pushbutton DET3TA)
P spike check Automatic (by pushbutton DET3TA)
Maximum current loop resistance 100 k-ohms at 50V, 50 k-ohms at 25 V and 5 k-ohms for 0.01 ohm resolution for readings below 19 ohms
Maximum voltage probe resistance 100 k-ohms at 50V, 50 k-ohms at 25 V and 5 k-ohms for 0.01 ohm resolution for readings below 19 ohms
Battery type 8 1.5 V AA cells (8 1.5 V AA NiMH rechargeable cells – DET4TCR2)
Battery life 3 hours, 700 consecutive tests
Safety EN61010-1 CAT IV 100 V
Terminals 4 mm plug type (test leads)
Ingress protection IP54
EMC Meets the requirements of EN61326-1:1998 for use in heavy industrial areas
Dimensions 8 x 5.7 x 3.2 in. (203 x 148 x 78 mm)
Weight 2.2 lb (1 kg)
Operating temperature range -.5º to +131º F (-15º to +55º C); DET3TA: -4º to +122º F (-20º to +50º C)
Storage temperature range -40º to +158º F (-40º to +70º C)
Humidity 95% RH non-condensing at 104º F (40º C)