HIOKI BT3563 6V/60V/300V Battery HiTester

HIOKI BT3563 6V/60V/300V Battery HiTester

Rp. 125,000,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.

Features:
High-voltage battery pack testing up to 300V
Ideal for high-precision cell voltage measurements (accurate to 0.01% of reading)
Ranges from 3 mΩ to 3000 Ω support coin-size to large-cell batteries
Battery module testing
Measurement circuitry employs enhanced current regulation
Fast 10 ms response and 8 ms sampling time for high-speed measurements
Large (low-resistance) cell testing
High-speed mass production testing of coin batteries
Fuel cell stack measurements
Battery research and development measurement applications
Choice of PC interfaces for full remote operation

The Hioki BT3563 6V/60V/300V Battery HiTester support simultaneous high-speed measurement of internal resistance (IR) and battery voltage (OCV) for the ever-expanding production lines of increasingly larger lithium-ion low resistance batteries, and other battery packs for high voltage applications.

Specifications:
Measurement types:  Resistance and voltage
Resistance measurement method:  Four-terminal AC (1-kHz) method
Rated voltage:  ±300V DC rated input voltage; ±300V DC maximum rated voltage to ground
Input resistance: 3mΩ/30mΩ/300mΩ ranges: Approx.90k; Ω3Ω/30Ω/300Ω/3000Ω ranges: Approx.1MΩ
Sampling rate:  Four steps – Extra Fast, Fast, Medium or Slow
Response time:  Approx. 10 ms for measurements. Note: Response time depends on reference values and the measurement object.
Total measurement time: Sampling time + Response time
Zero-adjustment:  1000-count range (both resistance and voltage)
Triggering:  Internal or external
Delay time:  On/off, 0 to 9.999 seconds
Averaging samples:  On/off, 2 to 16 samples
Statistical calculations:  Total data count; valid data count; maximum, minimum and average values; standard deviation; population standard deviation and process capability indices
Measurement value output function: Measurement values are output via RS-232C upon trigger input
Measurement value memory: Up to 400 measurements
Panel save/load: Up to 126 configuration settings
Save Frequently Used Settings in Memory: Measurement function, resistance measurement range, auto-range setting, zero-adjust setting data, sampling rate, trigger source, delay setting, averaging and comparator settings, statistical calculation setting, display switching and key-lock.
Analog Output :  Measured resistance (displayed value, from 0 to 3.1 V DC)
External interface:  External I/O, RS232C (9600, 19200 or 38400 bps), Printer RS-232C, GP-IB available on BT3562-01
Other functions: Over-range display, measurement error detection, self-calibration, dual comparators, key-lock