Categories
- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Water Sampler
- Weather Station
- Wood Moisture Meter
MEGGER digiPHONE+2 NTRX Set Acoustic and Electromagnetic Fault Location
Rp. 265,000,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The new digiPHONE+2. A combination of different methods for efficient noise damping enables perfect acoustics that lets you hear only the fault noise.
Acoustic-magnetic cable fault location
Highest acoustic noise immunity
Automatic filtering of interference signals
Automatic adjustment of all parameters, no adjustment necessary
Optional: Bluetooth® headphones
Optional: step voltage location (NT Set)
Optional: cable tracing (NTRX Set)
Indicator Unit
Power supply 6 x AA batteries, type IEC R6 (alkaline manganese)
Operating time >20 hours
Operating temperature -20°C to 55°C
Operating humidity Max. relative humidity 93% at 30°C
Storage temperature -30°C to 70°C
Display TFT colour display with 320 x 240 pixels
Weight <0.9 kg
Dimensions 225 mm x 65 mm x 100 mm (W x H x D)
Protection rating (according to IEC 60529 (DIN VDE 0470-1)) IP 54
Sensor Unit
Acoustic amplification >120 dB (facility for limiting amplification to 84 dB(A) can be switched on and off)
Dynamic range of the sensor Acoustic channel Magnetic channel >110 dB >110 dB
Frequency range of sensor 100 to 1,500 Hz
Filter stages
Low pass 100 to 400 Hz
Band pass 150 to 600 Hz
High pass 200 to 1,500 Hz
Weight (incl. telescopic handle) <2.2 kg
Dimensions 230 mm x 140 mm (Ø x H)
Protection rating (according to IEC 60529 (DIN VDE 0470-1)) IP 65 (only for plugged-in connector)