- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chart & Data Logger
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Current Load Bank
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Test Analyzer
- Oscilloscope
- Other Products
- PH Meter
- Pipe Cable Locator
- Power and Voltage
- Power Quality Meter
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Spectrum Analyzer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Water Sampler
- Weather Station
- Wood Moisture Meter
WTW 430IR Bench Laboratory Turbidity Meter
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
With the turbidimeters Turb® 430 T and Turb® 430 IR, the user has the choice to perform nephelometric measurements at 90° scattered light, according to the application and standard required.
The Turb® 430 IR meets the DIN 27027/ ISO7027 requirements, the Turb® 430 T those of US EPA 180.1. The measuring range is from 0 to 1100 NTU/ FNU and is identified automatically. Accurate measurements in the lower range, e.g. in drinking water, are easily achieved.
All measurements and menu driven 3-point calibration along with the easy functions for accurate and precise measurements require minimal training. The calibration is performed via an AMCO Clear® standards set ( 0.02-10-1000 NTU) . Up to 1000 data sets with ID numbers can be stored and output using the LabStation and powerful LSdata software.
The quality of the measurement results is supported by adjustable calibration intervals with documentation.
The Turb® 430 is not only a field measuring instrument ( especially with the practical field case) , but also a “ small lab instrument” for applications up to 1100 NTU/ FNU and with optimum data management.
Optional: single meter, field case with LSdata, accessories.
Measuring range
NTU 0 … 1100 / 0-1100
FNU 0 … 1100
Resolution
0.01 from 0.00 … 9.99
0.1 from 10 … 99.90
1 from 100 … 1100