HANNA HI88703 Bench Laboratory Turbidity Meter

HANNA HI88703 Bench Laboratory Turbidity Meter

Rp. 55,000,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.

The HI 88703 turbidity benchtop meter is specially designed for water quality measurements, providing reliable and accurate readings on low turbidity ranges.
This instrument has an EPA compliance reading mode which rounds the reading to meet EPA reporting requirements. Alternative EBC and Nephelos measuring units are available. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.

A two, three, four or five-point calibration could be performed by using the supplied standards. When user prepared standards are used, calibration points can be modified. H 88703 features complete GLP ( Good Laboratory Practice) functions that allows traceability of the calibration conditions. The last calibration points, time and date can be checked. Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.

Features: 
Two measuring ranges: Ratio turbidity, non-ratio turbidity
Meets USEPA requirements
GLP features
Two, three, four or five point turbidity calibration
USB PC connectivity
Log up to 200 measurements
Contextual help and tutorial mode

Specification:
Range    Non Ratio Mode    0.00 to 9.99; 10.0 to 40.0 NTU;
0.0 to 99.9; 100 to 268 Nephelos
0.00 to 9.80 EBC
Ratio Mode    0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU
0.0 to 99.9; 100 to 26800 Nephelos
0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
Resolution    Non Ratio Mode    0.01; 0.1 NTU 0.1; 1 Nephelos; 0.01 EBC
Ratio Mode    0.01; 0.1; 1 NTU 0.1; 1 Nephelos 0.01; 0.1, 1 EBC
Range Selection         automatic
Accuracy @25°C         ±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC)
±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC)
Repeatability         ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC)whichever is greater
Stray Light         < 0.02 NTU (0.15 Nephelos; 0.01 EBC)
Light Detector         silicon photocell
Method         Nephelometric method (90°) or Ratio Nephelometric Method(90° & 180°), Adaptation of the USEPA Method 108.1 and Standard Method 2130 B.
Measuring Mode         normal, average, continuous
Turbidity Standards         <0.1, 15, 100, 750 and 2000 NTU
Calibration         two, three, four or five-point calibration
Light Source/Life         tungsten filament lamp / greater than 100,000 readings
Display         40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
Log Memory         200 records
PC Interface         USB
Environment         0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply         230 V/50 Hz or 115 V/60 Hz 20 W; auto-off after 15 minutes of non-use
Dimensions         230 x 200 x 145 mm (9 x 7.9 x 5.7”)
Weight         2.5 Kg (88 oz.)

Includes: HI 88703-02 ( 230V) is supplied with sample cuvettes and caps ( 5) , calibration cuvettes, silicone oil ( HI 93703-58) , tissue for wiping cuvettes, power cord and instruction manual.