- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Water Sampler
- Weather Station
- Wood Moisture Meter
OAKTON WD-03316-80 Barometer with Digital Thermometer
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
The Oakton 03316-80 anaroid barometer has a barometric pressure range readout of 945 to 1045 mbar, and 27.9 to 30.9 inches Hg. Oakton barometers are used to measure atmospheric pressure and temperature in indoor applications. This barometer has a built-in, bi-metallic element for temperature compensation for the aneroid capsule for pressure reading accuracy. It has a selectable, digital LCD-display of C or F readings for ease of use, and wall-mounting for ease of reference. It is used to measure at an altitude between sea level and 2,000 feet. Batteries or external power are not required.
The 03316-80 anaroid barometer has a resolution of 0.5 mbar, 0.1 inches Hg, accuracy + or - 1.0 mbar between 970 and 1030 mbar; + or - 2.0 mbar beyond this range. Temperature range of -20 to 60 degrees C (-4 to 140 degrees F), resolution 0.1 degree C, accuracy + or - 1.0 degree C (+ or - 1.8 degrees F) with thermistor sensor (display digital LCD). Its body dimensions are 5.25 (D) x 1.25 (W) inches, and flange dimensions are 6.375 (outer diameter) x 0.15 (D) inches. It is used with one 1.5-V AA battery (included) which last for approximately one year, and it comes in an ABS plastic case.