Categories
- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Water Sampler
- Weather Station
- Wood Moisture Meter
THERMO SCIENTIFIC Orion AquaMate 8100 UV Vis Spectrophotometer
Rp. 235,000,000
NOTE
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
This high quality, reliable spectrophotometer incorporates advanced features and functions for the ultimate flexibility in operation. Operators can readily create their own custom methods. An included USB stick contains over 260 preprogrammed methods for easy and convenient measurements using Orion AQUAfast, Merck, CHEMetrics or Hach chemistries. You can download any or all of the preprogrammed methods you want.
Versatility:
Pre-programmed methods can also be adapted for new chemistries or operators can create their own custom methods and calibration curves
Instruments allow a one-point adjustment on any preprogrammed method to correct for variations in batch reagent chemistries
Wide variety of vial sizes can be used, including 10mm square vials, 20 and 50mm rectangular vials and an adjustable round vial holder that accommodates 13, 16, and 24mm round vials
Three USB connections provide the options to store methods and data to a USB memory stick, transfer data to a computer, and print hard copy data to an external printer
System is compatible with ink jet and laser printers with HP PCL 5 or greater
Verification:
Performance verification tests ensure wavelength accuracy and instrument functionality
Each verification report gives the time, date and instrument serial number in accordance with GLP and GMP
Built-in wavelength accuracy test is compatible with either the internal lamp or external calibrated standards
Built-in test methods for stray light, noise and resolution are available to validate instrument performance further
AquaMate 8100 spectrophotometer includes: Test Tube Holder for vials and test tube from 12 to 25 mm OD, 10 mm square single-cell holder, AquaMate Water Analysis Methods Software, Snap-on Printer, Dust Cover, External Power Supply, North America power cable (NEMA 5-15), European power cable (CEE 7/7), UK Power cable (BS 1362).
Specifications
Optical Design Dual beam – internal reference detector
Optical Detector Type Dual silicon photodiodes
Spectral Bandwidth 2.0 nm
Lamp (typical life) Xenon flash lamp (5 years)
Photometric:
Accuracy (Photometric) ±0.002A at 0.5A, ±0.004A at 1.0A, ±0.008A at 2.0A
Drift <0.0005A/hr
Linearity Up to 3.5A at 260nm
Noise ≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm
Range (Photometric) –2A to +3.5A; <1000 %T to 0 %T; 9999 C
Stray Light < 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2)
Wavelenght:
Accuracy 0.5 nm
Min. Data Interval 0.2; 0.5; 1.0; 2.0; 3.0; 5.0nm
Range 190 to 1,100nm
Repeatability <±0.2 nm
Scanning Speed 10 to 4,200 nm/nm
Slew Speed Slow, medium and fast (up to 1600 nm/min)