- Air Quality Meter
- Anemometer
- Battery Test & Analyzer
- Calibration Tester
- Chlorine Meter
- Clamp Meter
- Coating Thickness
- Concrete Meter
- Conductivity Meter
- Current & Echosounder
- Current Injection Test
- Deadweight Tester
- Density Meter
- Dew Point Hygrometer
- Dissolved Oxygen
- Fault Finder Locator
- Flaw Detector
- Flow Meter
- Force Gauge
- Gas Analyzer
- Gauss Meter
- Grain Moisture
- Ground Resistance
- Hand Pump
- Hardness Tester
- High Voltage Rercue
- Hipot Tester
- Holiday Detector
- Insulation Tester
- Leak Detection
- Level Lube Controller
- Light Meter
- Manometer
- Multimeter
- Networks Analyzer
- Ohm Meter
- Oil Content Analyzer
- Other Products
- PH Meter
- Pipe Cable Locator
- Power Quality Analyzer
- Pressure Gauge
- Rangefinder
- Shaft Alignment
- Sound Level Meter
- Spectrophotometer
- Stroboscope
- Tachometer
- Temp. Calibrator
- Thermal Imager
- Thermohygrometer
- Thermometer
- Torque Tester
- Turbidity Meter
- Ultrasonic Thickness
- Vibration Analyzer
- Video Borescope
- Water Level Meter
- Water Quality Meter
- Water Sampler
- Weather Station
- Wood Moisture Meter
SCHONSTEDT TraceMaster II Pipe and Cable Locator
Harga dapat berubah sewaktu-waktu mengikuti perkembangan kurs rupiah terhadap mata uang asing lainnya sehingga sangat mungkin terjadi adanya perbedaan harga yang berlaku dengan harga yang tertera pada website kami.
Features:
Designed to withstand the rigors of daily on-site usage and a wide range of environmental conditions
The receiver's LCD panel is uncomplicated and intuitive with only two buttons (frequency and depth) and two knobs (gain and volume)
Receiver can operate in manual or automatic gain modes
When in active mode, the receiver can operate in three frequencies: Mid-range frequency (8 kHz) — This frequency will not usually jump to adjacent conductors, but may jump across non-conductive joints in a pipe for longer tracing. It is a good general-purpose frequency for medium length tracing in areas with low congestion.; Low frequency (575 Hz) — This frequency will not jump to adjacent conductors and is typically used with good conductors, in congested areas, or when a long distance trace is required.; High frequency (82 kHz) — This frequency can typically jump to adjacent conductors and is commonly used for short tracing in poor conductors, such a cast iron and other similar pipes.
No transmitter settings are required
Transmitter case has a built-in storage compartment for cables, ground stake and inductive clamps (sold separately)
The Schonstedt Tracemaster II is the first pipe and cable locator on the market to offer a remote link between the transmitter and the receiver units. Schonstedt's most popular TraceMaster, the TMS-001-AF is capable of operating in three frequencies (575 Hz, 8 kHz, 82 kHz), making it an ideal choice for electric, telecommunications and water/gas/sewer applications. With three classes of frequencies, it's the most versatile locator on the market.
Includes:
Receiver
Transmitter built into a hard carrying case (Tx5)
Transmitter case carrying strap (S00024)
Padded receiver carrying case
Conductive clip assembly (TM70000)
Ground stake (208263)
8 AA batteries for the receiver
1 rechargeable NiMH pack for the transmitter
3" inductive signal clamp (TM60000) is sold separately
5" inductive signal clamp (TM60001) is sold separately
7" inductive signal clamp (TM60002) is sold separately
Specifications: Receiver: Operating Voltage: 12 V (8 “AA” alkaline batteries). Battery Life: 60 hours (alkaline batteries, intermittent usage @ 70°F). Audio Output:10 - 3000 Hz determined by signal strength, 0 - 70 db SPL (Sound Pressure Level), volume controlled. Weight (incl. batteries): 3.9 lb. (1.7 kg.). Operating Temp.: -4°F to 140°F (-20°C to 70°C). Overall Dimensions: 29.5” L x 5.0” W x 2.2” D (75 cm L x 12.7 cm W x 5.6 cm D). Max. Depth Capability: 19’ 11” (6.1 m) at 575 Hz, 8 kHz, 82 kHz and Passive. Sensors: Peak and Null. RF Link Frequency: Spread Spectrum ISM band (902 MHz to 928 MHz). RF Link Range: 1000' line of sight or better (nominal) Transmitter: Charger input voltage: 22-30 VDC, 1.5 Amperes. Operating Voltage: 12 V, rechargeable NiMH pack. Battery Life: 8 hours (intermittent usage @ 70º F). Weight (incl. Batteries): 9.1 Lb (4.1 kg). Operating Temperature: -4º F to 140º F (-20º C to 70º C). Overall Dimensions: 14” W x 10.5” D x 6” H (35.5 cm x 27 cm x 15 cm). Resistance Measuring Range: 500 Ω to 5 MΩ. Backlighting: White LED array, ambient light sensing. Environmental: IEC 605 29, IP56, Mil-Std 810F. Voltage Measuring Range: 0-260 VAC and 0-60VDC. Maximum Output Voltage: 100 V RMS. Operating Frequencies: 575 Hz, 8 kHz, and 82 kHz. Output Power: (Conductive Mode) 1 W maximum at 82 kHz (FCC limited); Selectable 1 W, 2 W or 5 W max. at 575 Hz and 8 kHz. Operating Modes: Conductive: All frequencies; Inductive: 82 kHz only; Inductive Clamp (optional): 8 kHz and 82 kHz. RF Link Frequency: Spread Spectrum ISM band (902 MHz to 928 MHz). RF Link Range:1000' line of sight or better (nominal).